Lowering Emissions in a Short, Natural Draft TLUD

Lowering Emissions in a Short, Natural Draft TLUD

The great thing about 12” high tincanium natural draft TLUDs is that they are cheap, short and powerful. Dr. Tom Reed had a dream that a billion TLUDs would protect health, save wood, etc. We wondered if an all Tier 4, affordable, stainless steel ND-TLUD might help?

The first step was to test the baseline ND-TLUD. It’s great for camping outdoors but not close to Tier 4 for PM2.5, CO and Thermal Efficiency. We are now trying three ways to achieve all Tier 4:

  1. A nothing fancy prototype. Control primary and secondary air and don’t let flames touch the bottom of the pot.
  2. A static mixer prototype
  3. A better concentrator ring prototype.

Usually when we make one change a day in a prototype and test the effects under the emission hood it takes about a month to get close to an “optimal” solution. Doing one iteration a day leaves us time to do all the other work here at the lab. 

Looking forward to sharing test results! 